View times:
Model: JP501D
Structure: Spoke & Round Style
 
Precision: G1, G2, G3
Measure Range: 1MN~5MN


Spoke & Round style design, available in the manifold accurate, measurement in the capacities 1MN to 5MN, convenient installation, can be used in atrocious environments and hazardous areas.
Capacity MN 1/2/3/4/5
Accuracy   G1 G2 G3
Combined error (%FS) 0.1% 0.2% 0.3%
Creep (%FS/30min) 0.05% 0.05% 0.05%
Temperature effect on sensitivity (%FS/10℃) 0.05% 0.1% 0.2%
Temperature effect on zero (%FS/10℃) 0.05% 0.1% 0.2%
Output sensitivity (mv/v) ≥ 2.0
Input resistance (Ω) 1072±5
Output resistance (Ω) 1050±5
Insulation resistance (MΩ) ≥ 5000(50VDC)
Zero balance (%FS) 1.0
Temperature,compensated (℃) -10~+40
Temperature,operating (℃) -35~+65
Excitation,Recommended (V) 5~12(DC)
Excitation,Max (V) 18(DC)
Safe overload (%FS) 150
Ultimate overload (%FS) 300