JY500D4 digital weighing converter is mainly used as part of a weighing device to convert between a weighing signal and a digital signal. With functions of weight limit judgment and latch display, it can be used for weight limit control and
Instruction Manuals:
Asked price:longxin@meterforall.com
Contact us instantly:             
  • Application
  • Features
  • Dimensions
  • Parameters
JY500D4 digital weighing converter is mainly used as part of a weighing device to convert between a weighing signal and a digital signal. With functions of weight limit judgment and latch display, it can be used for weight limit control and data acquisition.
With two rows of LED nixie tubes for display, four control buttons and a panel-mount structure, the products is applicable to the automatic weighing apparatuses in industries including building materials, chemical, food, steel and iron, feed, etc.

View times:
● Used for places needing to convert weighing signals into digital communication signals and standard analog output signals.
●4-20mA (type A) or 1-5V (type B) analog output signal , RS485, RS232 (type S) or DP (D4D type)digital communication interface.
● Two rows of LED nixie tubes for displaying current weighing value, latched value or analog output value
● 4 control buttons, i.e. ZERO, TARE, LATCH and DISPLAY.
●Two weight limit judgment functions, i.e. upper limit and lower limit,judgment results output three NPN (D4D type is PNP) transistor ports.
● With an isolated input for receiving external zero-setting signal, taring signal or latch control signal.
● Can latch 160 weighing values automatically. “first-in, first-out” and push operation of data for the purpose of future reference. Data getting rate is up to 120 samples per second.
● Can obtain appropriate performance through parameter setting.
● Interior switching power supply and overvoltage protection circuit to adapt to large voltage fluctuation.
● Panel-mount type. Panel size: 110mm (W) and 62 mm (D).
Basic parameters  
Display window Two rows of LED nixie tubes display; text height: 9mm/7.5mm
Scale interval 1, 2, 5, 10,20 and 50
Maximum weighed value ≤d×10000 + 9d
Position of the decimal point 0, 0.0, 0.00, 0.000 and 0.0000
Product weight About 0.5kg
Analog and AD performance indexes  
Static accuracy grade Meet third-class weighing instrument requirement
Maximum signal input range 0.02mV/V ~ 2.5 mV/V (equivalent to 0.1mV ~ 12.5mV)
Maximum sensitivity 1.5μV/d (filter factor =1) or 0.75μV/d (filter factor =32)
Noise at the input end ≤0.5μVp-p (filter factor =1), or ≤0.25μVp-p  (filter factor =32)
Zero drift ≤0.05μV/°C (@ 0.02mV/V)
Range temperature coefficient ≤10ppm/°C
Input impedance of the sensor interface ≥20MΩ
Nonlinear error ≤0.002%FS
A/D conversion speed 120 SPS
Analog output performance indexes  
Composite error ≤1%FS (load resistance of type A: 0Ω)
Nonlinear error ≤0.1%FS
Zero drift ≤10μA/°C
Range temperature coefficient ≤0.02%FS/°C
Operating parameters  
Communication Baud rate of communication 1200/2400/4800/9600/19200/38400
1,200/2,400/4,800/9,600/19,200/38,400
 
Byte structure
 
Multiple options
Odd-even check Checksum, settable
Data format Multiple options
Weighing sensor Type Resistance strain weighing sensor
Excitation source DC 5V, 60mA, four parallel 350Ω sensors
I/O end Load capacity of the output end 24V/0.1A
Current of the input end 24V/5mA
Operating conditions  
Power supply AC 220V (AC175-245V), 50Hz/60Hz
Power ≤10W
Operating temperature -25°C~40°C
 
Humidity
≤90%RH (no condensate)