JY500B1 Belt Scale Controller Weighing Transmitter System Menu
JY500B1 Belt Scale Controller Weighing Transmitter System Menu
1 Display Events
All important scale functions are internally monitored. Errors are reported by events message.
2 Stop/Start Prefeeder
If the belt feeding end configured with feeder (prefeeder), only choose start“prefeeder”. When instrument stop / start operating, its X6 "prefeeder ports start" port have close/ disconnect switching value action, used to start / stop control prefeeder. When instrument check tare (self weight), should choose “stop prefeeder”, prefeeder will stop operating, instrument to accurately detect the tare.
3 Service values
Instrument stores state information for the current system, use the menu,state information are reported by service values.
4 Stop/Start Volum Mo
Weight Measuring Mo (stop Volum Mo) is the control mode. Instrument real-time output control signal according to preset flow settings, or adjust belt speed or adjust the feed rate of prefeeder.
Volum Mo is uncontrollable mode. Instrument will be at load rating value (parameter D01) for belt load value, output fixed control signal to control belt speed and prefeeder according to preset flow set value proportional conversion.
5 Stop/Start Volum Sy
In contrast to Volumetric mode where the conveyor belt will directly run with the last speed of setpoint in Volumetric Synchronous Mode to save time for the PID adjustment. Let the feed rate reach the set point quickly. If stop the Volum Sy mode, the system speed will from the 0 to the set point gradually by the PID adjustment.
6 Stop/Start Mode
To select system stop/start control source in system menu, including keyboard, serial port, port. When stop/start mode selected keyboard or serial port or port, system info area appears corresponding identifier.
7 Select Batch
Exit continuous feeding and enter batch feeding way.
8 Parameters
Enter view, modify, reinstall the operating parameters.
9 Calibra Functions .
Enter the system calibration weighing calibration operation.
10 Print FMZ
If configure printer, Z0, Z1, Z2, Z3 result can be printed.