Maintenance of Dynamic Weighing Instrument

This paper discusses the electronic truck scale dynamic weighing instrument, its operation and control system, microcomputer and so on installation, use, maintenance and maintenance.

Dynamic weighing instrument maintenance

(1) ensure the instrument 220V power supply is stable and reliable.Frequently check whether the wiring is loose, broken, grounding wire is firm.

(2) When the instrument is not used for a long time (such as more than one month), it should be energized and checked according to the environmental conditions to avoid the reliability affected by moisture or other undesirable gas erosion.

(3) the dynamic weighing instrument should be kept away from the heat source and vibration source.

(4) There should be no flammable and explosive gas or dust in the use environment.

(5) The same phase line of the weighing controller shall not be connected with inductive load, such as doorbell, etc.

(6) When the weighing control instrument is not used for a long time, the fuse is replaced, the position is moved or the dust is removed, the power must be cut off.

(7) If the instrument fails, the power should be cut off quickly, and then the professional departments and personnel should be informed to check and organize. Users are not allowed to open the case at will, let alone replace the internal parts at will.

(8) The operator and instrument maintenance personnel shall be specially trained to operate and maintain instruments.

Dynamic weighing instrument control system maintenance

(1) After installation, the weighing instrument should properly keep the manual, certificate of qualification, installation drawing and other materials, and be verified by the local measuring department or the state-recognized measuring department, before it is put into use.

(2) Before the meter is powered on, it is necessary to check whether the grounding device of the power supply is reliable;Power must be cut off after off-duty shutdown.

(3) Before using the weighing device, check whether the scale body is flexible and whether the performance of the supporting parts is good.

(4) the dynamic weighing instrument must be turned on first to preheat, generally about 30 minutes.

(5) In order to ensure accurate measurement of the system, there should be lightning protection facilities. When welding near the weighing device, it is strictly prohibited to borrow the scale platform for zero line grounding to prevent damage to the electrical components.

(6) for the ground balance installed in the field, the drainage device in the foundation pit should be checked regularly to avoid blockage.

(7) to keep the instrument junction box dry, once the junction box inside the wet air and water immersed, can be used to dry the hair dryer.

(8) In order to ensure the normal measurement of the weighing instrument, it should be calibrated regularly.

(9) when lifting metering weight, there should be no impact phenomenon;When measuring vehicular heavy objects, should not exceed the rated scale of the system.

(10) axle load of truck scale dynamic weighing instrument is related to sensor capacity, sensor fulcrum distance and other factors.General truck scale prohibited near the maximum volume of forklifts such as short wheelbase vehicles balance.

(11) The weighing operator and instrument maintenance personnel shall read the manual and relevant technical documents carefully before starting to operate.

Car scale platform maintenance

(1) there shall be no stones, coal and other foreign bodies in the clearance around the weighing platform.No soil clods under the weighing platform.

(2) often check whether the limit clearance is reasonable, and the limit bolt and the scale body should not collide and contact.

(3) the connector shall be maintained once every six months, and the connecting part shall be coated with butter.

(4) Arc welding operation is prohibited on the weighing platform, if it is necessary to conduct arc welding operation on the weighing platform.Please note the following points :(Disconnect the signal cable from the dynamic weighing meter;The ground wire of arc welding must be set near the welding site, and firmly in contact with the scale body;Do not use sensors as part of the arc welding loop.

Car scale control instrument microcomputer maintenance

(1) to ensure that the instrument control microcomputer grounding system is good.

(2) it is strictly prohibited to switch frequently, move and remove the computer at will.

(3) the weighing system control computer should be away from the water source, strong electromagnetic dry close.

(4) it is strictly prohibited to use foreign floppy disks at will to prevent infection with viruses.

(5) Do not use hard objects to hit the keyboard, such as a screwdriver.

(6) The room shall be kept clean and the temperature shall meet the requirements of the host manual.

(7) Operators need to be trained before they can take up their posts.

 

NOTICE: This site is reproduced by the editor of this website. The purpose of the reprint is to transmit more information. It does not mean that this website agrees with its views and is responsible for its authenticity. If you are involved in the content, copyright and other issues, please contact us within 30 days, we will delete the content in the first time! [Declaration] The copyright of this article belongs to the original author. The content is the author's personal opinion. This site is only for reference and does not constitute any investment and application advice. This site has the final interpretation of this statement.

 

CATEGORIES

CONTACT US

Contact: Celia

Phone: +86-13825212800

Tel: +86-13825212800

Email: sales3@meterforall.com

Add: Floor 6 ,Building 11,Longbi Industrial zone, Bantian Street, Longgang District, Shenzhen, China

Scan the qr codeClose
the qr code